RICERCA 2019
OSSERVAZIONE DELLA RISPOSTA DELL’IMPIANTO FOGNARIO DI BAZZANO AL TERREMOTO DELL’AQUILA DEL 2009
Roberto Guidotti, 
Catastrophe Risk Research Analyst, Guy Carpenter & Company, LLC, New York, NY, USA
roberto.guidotti@guycarp.com
Alberto Castellani
Retired, Politecnico di Milano, Structural Engineering Department, Milano, Italy
alberto.castellani@polimi.it
Structural 221 | Gennaio - Febbraio  2019
10.12917/Stru221.02 – https://doi.org/10.12917/STRU221.02

L’articolo presenta i danni ad un impianto fognario di alcuni km di lunghezza, costruito seguendo le procedure correnti, osservati pochi mesi dopo il terremoto dell’Aquila del 2009. L’ispezione è stata effettuata mediante dispositivo telecomandato. La porzione di condotte di polivinilcloruro (PVC) e di polietilene ad alta densità (HPDE) mostra ovalizzazioni significative. L’ispezione mostra un limitato danneggiamento alle condotte in calcestruzzo, ad eccezione di determinate sezioni, interessate dallo scorrimento della vicina faglia di Bazzano. Un danneggiamento severo alle giunzioni tra tubo e tubo è ascrivibile allo spostamento relativo ed alla curvatura imposti dal sisma al suolo. L’articolo discute le condizioni di carico sismico per condotte sotterranee imposte dallo Eurocode 8. Quantunque l’impianto fognario non sia stato progettato secondo tali condizioni di carico, l’ispezione fornisce una validazione sperimentale delle condizioni più significative in fase progettuale: la frattura del terreno e la variazione da punto a punto del moto sismico (effetto del passaggio d’onda).

ARTICOLO SOLO IN LINGUA INGLESE
 

ARGOMENTO:  DIAGNOSTICS, STRUCTURAL MONITORING - DIAGNOSTICA, MONITORAGGIO,STEEL ALUMINIUM AND STEEL CONSTRUCTION - ACCIAIO, ALLUMINIO E COSTRUZIONI METALLICHE,SEISMIC - SISMICA
PAROLE CHIAVE: Condotte interrate, azione sismica, moto relativo del terreno, passaggio d’onda
Abstract
x
OBSERVED RESPONSE OF THE SEWAGE NETWORK OF BAZZANO DURING THE APRIL 2009 L’AQUILA EARTHQUAKE

The paper presents damage of buried pipelines built according to current procedures, observed few months after the 2009 L’Aquila earthquake. The paper illustrates pictures from a visual inspection through remote-controlled camera of an important buried pipeline of the sewage pipeline network of Bazzano, near L’Aquila, of some km length. Almost all the pipes made of polyvinyl chloride (PVC) and high-density polyethylene have shown significant out-of-roundness. The survey shows a limited damage of the concrete made pipes, with some sections experiencing a more considerable damage, likely due to a slip of the nearby fault of Bazzano. The most severe damage at the gasket between pipes is ascribed to curvature or elongation, imposed by the earthquake to the ground. Seismic load conditions listed in the Eurocode 8 for a buried pipeline are presented and discussed. The visual inspection of the pipeline system provides experimental validation of the calculation models based on Eurocode 8 for the most significant conditions in the design process: the ground rupture and the different ground motion from point to point (wave-passage effect).

KEYWORDS: Pipe lines, seismic action, relative soil displacement, wave passage
Sei già abbonato al Magazine o registrato?
Do you have an account or a subscription?
Sign in
Vuoi acquistare degli articoli?
ARCHIVIO STRUCTURAL: seleziona e scarica fino a 5 o 10 articoli pubblicati, in formato PDF (escluso l'anno in corso).
Buy your articles
Structural ARCHIVES: select and download up to 5 or 10 articles, in PDF format (excluding the current year).
5 ARTICLES - 15,00 €
10 ARTICLES - 25,00 €
Se sei interessato alla consultazione degli articoli più recenti, visita la sezione MAGAZINE.
Visit the MAGAZINE section for the most recent articles.